CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageFlexFlashDriveControllerIndex

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageFlexFlashDriveControllerIndex

cucsStorageFlexFlashDriveControllerIndex

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveControllerIndex

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.36.1.6

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS storage:FlexFlashDrive:controllerIndex managed object property

What is cucsStorageFlexFlashDriveControllerIndex?

This reports the numeric index of the FlexFlash controller that this physical drive is attached to. An admin uses this to correlate a specific FlexFlashDrive row with its correct parent controller when a server hosts more than one such controller. On a server with a single embedded FlexFlash controller, every physical drive under it would report the same controllerIndex value.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.36.1.6
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveControllerIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.36.1.6.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveControllerIndex.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveControllerIndex OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.36cucsStorageFlexFlashDriveTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.36.1cucsStorageFlexFlashDriveEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.36.1.6cucsStorageFlexFlashDriveControllerIndexCISCO-UNIFIED-COMPUTING-STORAGE-MIB