CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageFlexFlashControllerWriteErrorThreshold

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageFlexFlashControllerWriteErrorThreshold

cucsStorageFlexFlashControllerWriteErrorThreshold

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerWriteErrorThreshold

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.35.1.28

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS storage:FlexFlashController:writeErrorThreshold managed object property

What is cucsStorageFlexFlashControllerWriteErrorThreshold?

This holds the configured write-error threshold at the controller level for this FlexFlash controller, the number of write errors tolerated before a fault is raised. An admin tunes this threshold to control how aggressively the controller reports developing write reliability problems across its attached cards. A controller closing in on this writeErrorThreshold is a stronger indication of overall subsystem wear than watching a single card's counter alone.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.35.1.28
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerWriteErrorThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.35.1.28.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerWriteErrorThreshold.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsStorageFlexFlashControllerWriteErrorThreshold.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerWriteErrorThreshold OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.35cucsStorageFlexFlashControllerTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.35.1cucsStorageFlexFlashControllerEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.35.1.28cucsStorageFlexFlashControllerWriteErrorThresholdCISCO-UNIFIED-COMPUTING-STORAGE-MIB