All MIBs › CISCO-UNIFIED-COMPUTING-STORAGE-MIB › cucsStorageFlexFlashControllerPhysicalDriveCount
cucsStorageFlexFlashControllerPhysicalDriveCount
Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerPhysicalDriveCount
OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.35.1.15
Node type: OBJECT-TYPE
Type: Gauge32
Access: read-only
Description: Cisco UCS storage:FlexFlashController:physicalDriveCount managed object property
What is cucsStorageFlexFlashControllerPhysicalDriveCount?
This reports the number of physical SD card drives this FlexFlash controller currently detects attached to it. An admin checks this to confirm both cards in an expected mirrored pair are actually being seen by the controller, rather than just one. A controller reporting a physicalDriveCount of 1 when two cards are supposed to be installed tells an admin one card isn't being detected.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.35.1.15 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerPhysicalDriveCount
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.35.1.15.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerPhysicalDriveCount.1
Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerPhysicalDriveCount OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.45 | cucsStorageObjects | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.35 | cucsStorageFlexFlashControllerTable | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.35.1 | cucsStorageFlexFlashControllerEntry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.35.1.15 | cucsStorageFlexFlashControllerPhysicalDriveCount | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |