All MIBs › CISCO-UNIFIED-COMPUTING-STORAGE-MIB › cucsStorageFlexFlashControllerOperability
cucsStorageFlexFlashControllerOperability
Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerOperability
OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.35.1.11
Node type: OBJECT-TYPE
Type: CucsEquipmentOperability
Access: read-only
Description: Cisco UCS storage:FlexFlashController:operability managed object property
What is cucsStorageFlexFlashControllerOperability?
This reports the CucsEquipmentOperability of this FlexFlash controller — UCSM's judgment of whether the controller itself is operable, degraded, or inoperable. An admin checks this alongside controllerHealth to build a full picture of whether the embedded FlexFlash subsystem on this server can be trusted for boot storage. A controller that transitions to a degraded operability value is a stronger signal to an admin than a single card issue, since it can affect both mirrored cards at once.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.35.1.11 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerOperability
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.35.1.11.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerOperability.1
Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerOperability OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.45 | cucsStorageObjects | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.35 | cucsStorageFlexFlashControllerTable | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.35.1 | cucsStorageFlexFlashControllerEntry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.35.1.11 | cucsStorageFlexFlashControllerOperability | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |