CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageFlexFlashControllerId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageFlexFlashControllerId

cucsStorageFlexFlashControllerId

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.35.1.7

Node type: OBJECT-TYPE

Type: CucsStorageFlexFlashControllerId

Access: read-only

Description: Cisco UCS storage:FlexFlashController:id managed object property

What is cucsStorageFlexFlashControllerId?

This holds the numeric identifier UCSM assigned to this FlexFlash controller. An admin uses this id to distinguish this controller instance when a server board hosts more than one FlexFlash controller, such as in multi-node systems. Two FlexFlash controllers on different boards of the same chassis would each carry their own distinct id value.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.35.1.7
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.35.1.7.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerId.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerId OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.35cucsStorageFlexFlashControllerTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.35.1cucsStorageFlexFlashControllerEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.35.1.7cucsStorageFlexFlashControllerIdCISCO-UNIFIED-COMPUTING-STORAGE-MIB