All MIBs › CISCO-UNIFIED-COMPUTING-STORAGE-MIB › cucsStorageFlexFlashControllerId
cucsStorageFlexFlashControllerId
Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerId
OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.35.1.7
Node type: OBJECT-TYPE
Type: CucsStorageFlexFlashControllerId
Access: read-only
Description: Cisco UCS storage:FlexFlashController:id managed object property
What is cucsStorageFlexFlashControllerId?
This holds the numeric identifier UCSM assigned to this FlexFlash controller. An admin uses this id to distinguish this controller instance when a server board hosts more than one FlexFlash controller, such as in multi-node systems. Two FlexFlash controllers on different boards of the same chassis would each carry their own distinct id value.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.35.1.7 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerId
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.35.1.7.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerId.1
Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashControllerId OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.45 | cucsStorageObjects | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.35 | cucsStorageFlexFlashControllerTable | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.35.1 | cucsStorageFlexFlashControllerEntry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.35.1.7 | cucsStorageFlexFlashControllerId | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |