CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageFlexFlashCardNumberOfBlocks

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageFlexFlashCardNumberOfBlocks

cucsStorageFlexFlashCardNumberOfBlocks

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashCardNumberOfBlocks

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.34.1.14

Node type: OBJECT-TYPE

Type: Unsigned64

Access: read-only

Description: Cisco UCS storage:FlexFlashCard:numberOfBlocks managed object property

What is cucsStorageFlexFlashCardNumberOfBlocks?

This reports the total number of addressable blocks on this FlexFlash SD card. Combined with the card's block size, an admin uses this to calculate the card's raw storage capacity available for the embedded OS or hypervisor image. A replacement card reporting a lower numberOfBlocks than the card it replaced would mean less usable capacity for the embedded image.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.34.1.14
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashCardNumberOfBlocks

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.34.1.14.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashCardNumberOfBlocks.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashCardNumberOfBlocks OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.34cucsStorageFlexFlashCardTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.34.1cucsStorageFlexFlashCardEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.34.1.14cucsStorageFlexFlashCardNumberOfBlocksCISCO-UNIFIED-COMPUTING-STORAGE-MIB