All MIBs › CISCO-UNIFIED-COMPUTING-STORAGE-MIB › cucsStorageEnclosureVoltage
cucsStorageEnclosureVoltage
Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageEnclosureVoltage
OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.12.1.24
Node type: OBJECT-TYPE
Type: CucsEquipmentSensorThresholdStatus
Access: read-only
Description: Cisco UCS storage:Enclosure:voltage managed object property
What is cucsStorageEnclosureVoltage?
This OID gives voltage sensor threshold status for the Enclosure object, a CucsEquipmentSensorThresholdStatus value showing whether the enclosure's supply voltage sensor sits within its configured normal range. Admins monitor this because a voltage anomaly at the enclosure level can put every drive it powers at risk simultaneously. For example, voltage crossing into a critical state on an enclosure would justify checking its shared power supply before any individual drive troubleshooting.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.12.1.24 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageEnclosureVoltage
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.12.1.24.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageEnclosureVoltage.1
Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageEnclosureVoltage OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.45 | cucsStorageObjects | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.12 | cucsStorageEnclosureTable | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.12.1 | cucsStorageEnclosureEntry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.12.1.24 | cucsStorageEnclosureVoltage | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |