CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageEnclosureAdminState

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageEnclosureAdminState

cucsStorageEnclosureAdminState

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageEnclosureAdminState

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.12.1.14

Node type: OBJECT-TYPE

Type: CucsStorageEnclosureAdminState

Access: read-only

Description: Cisco UCS storage:Enclosure:adminState managed object property

What is cucsStorageEnclosureAdminState?

This OID reports adminState for the Enclosure object, a CucsStorageEnclosureAdminState value showing the administrator-configured state (such as enabled or disabled) for this drive enclosure. Admins set and check this when deliberately taking an enclosure out of service for maintenance without physically removing it. For example, setting adminState to disabled before servicing a disk shelf prevents UCSM from raising unnecessary faults during the maintenance window.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.12.1.14
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageEnclosureAdminState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.12.1.14.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageEnclosureAdminState.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageEnclosureAdminState OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.12cucsStorageEnclosureTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.12.1cucsStorageEnclosureEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.12.1.14cucsStorageEnclosureAdminStateCISCO-UNIFIED-COMPUTING-STORAGE-MIB