CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageDiskEnvStatsTemperature

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageDiskEnvStatsTemperature

cucsStorageDiskEnvStatsTemperature

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageDiskEnvStatsTemperature

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.50.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS storage:DiskEnvStats:temperature managed object property

What is cucsStorageDiskEnvStatsTemperature?

This OID returns the current temperature reading for the DiskEnvStats object, an INTEGER giving the physical disk's measured temperature at the last poll. Admins watch this per-disk value directly because sustained high disk temperature accelerates wear and increases failure risk, especially in dense enclosures. For example, a disk consistently reading a much higher temperature than its enclosure siblings may indicate a local airflow blockage around that slot.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.50.1.6
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageDiskEnvStatsTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.50.1.6.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageDiskEnvStatsTemperature.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageDiskEnvStatsTemperature OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.50cucsStorageDiskEnvStatsTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.50.1cucsStorageDiskEnvStatsEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.50.1.6cucsStorageDiskEnvStatsTemperatureCISCO-UNIFIED-COMPUTING-STORAGE-MIB