CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageControllerSubOemId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageControllerSubOemId

cucsStorageControllerSubOemId

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerSubOemId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.1.1.47

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS storage:Controller:subOemId managed object property

What is cucsStorageControllerSubOemId?

This OID reports subOemId for the storage Controller, a Gauge32 sub-OEM identifier distinguishing rebranded or OEM-variant firmware/hardware builds of an otherwise identical controller chipset. Admins consult this when a support case needs to distinguish which OEM build of the controller is installed, since firmware update paths can differ by sub-OEM. For example, applying the wrong firmware package because subOemId was ignored can brick a controller, so support teams check it first.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.1.1.47
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerSubOemId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.1.1.47.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerSubOemId.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerSubOemId OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.1cucsStorageControllerTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.1.1cucsStorageControllerEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.1.1.47cucsStorageControllerSubOemIdCISCO-UNIFIED-COMPUTING-STORAGE-MIB