CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageControllerPerf

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageControllerPerf

cucsStorageControllerPerf

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerPerf

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.1.1.10

Node type: OBJECT-TYPE

Type: CucsEquipmentSensorThresholdStatus

Access: read-only

Description: Cisco UCS storage:Controller:perf managed object property

What is cucsStorageControllerPerf?

This OID gives the perf sensor threshold status of the storage Controller, a CucsEquipmentSensorThresholdStatus value indicating whether the controller's performance sensor is within its configured normal, warning, or critical bounds. Monitoring this lets an admin catch a RAID controller that is becoming a performance bottleneck before it visibly slows down disk I/O for the host. For example, perf flipping to a critical threshold state on a busy controller would justify checking queue depth or offloading virtual drives to another controller.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.1.1.10
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerPerf

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.1.1.10.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerPerf.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerPerf OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.1cucsStorageControllerTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.1.1cucsStorageControllerEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB