CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageControllerFaultMonitoring

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageControllerFaultMonitoring

cucsStorageControllerFaultMonitoring

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerFaultMonitoring

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.1.1.20

Node type: OBJECT-TYPE

Type: CucsStorageControllerFaultMonitoring

Access: read-only

Description: Cisco UCS storage:Controller:faultMonitoring managed object property

What is cucsStorageControllerFaultMonitoring?

This OID reports faultMonitoring for the storage Controller, a CucsStorageControllerFaultMonitoring value showing whether the controller's built-in fault-monitoring feature is enabled or disabled. Admins care because a controller with fault monitoring disabled will not proactively surface predictive drive failures through UCS Manager. For example, if disk failures on an array are going unnoticed, checking cucsStorageControllerFaultMonitoring can reveal that monitoring was inadvertently turned off.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.1.1.20
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerFaultMonitoring

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.1.1.20.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerFaultMonitoring.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerFaultMonitoring OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.1cucsStorageControllerTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.1.1cucsStorageControllerEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.1.1.20cucsStorageControllerFaultMonitoringCISCO-UNIFIED-COMPUTING-STORAGE-MIB