CISCO-UNIFIED-COMPUTING-NETWORK-MIB :: cucsNetworkSanNeighborEntryFiPortDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-NETWORK-MIBcucsNetworkSanNeighborEntryFiPortDn

cucsNetworkSanNeighborEntryFiPortDn

Module: CISCO-UNIFIED-COMPUTING-NETWORK-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-NETWORK-MIB::cucsNetworkSanNeighborEntryFiPortDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.32.6.1.7

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS network:SanNeighborEntry:fiPortDn managed object property

What is cucsNetworkSanNeighborEntryFiPortDn?

This OID reports, as an SnmpAdminString, the Distinguished Name of the specific Fabric Interconnect SAN port on which this Fibre Channel neighbor was discovered. An admin uses this DN to map a discovered SAN neighbor entry back to the exact local uplink port it was seen on. For example, given several SanNeighborEntry rows, this fiPortDn field is what lets an admin say definitively which physical SAN uplink each upstream fabric switch is connected to.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.32.6.1.7
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-NETWORK-MIB::cucsNetworkSanNeighborEntryFiPortDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.32.6.1.7.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-NETWORK-MIB::cucsNetworkSanNeighborEntryFiPortDn.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-NETWORK-MIB::cucsNetworkSanNeighborEntryFiPortDn OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.32cucsNetworkObjectsCISCO-UNIFIED-COMPUTING-NETWORK-MIB
1.3.6.1.4.1.9.9.719.1.32.6cucsNetworkSanNeighborEntryTableCISCO-UNIFIED-COMPUTING-NETWORK-MIB
1.3.6.1.4.1.9.9.719.1.32.6.1cucsNetworkSanNeighborEntryEntryCISCO-UNIFIED-COMPUTING-NETWORK-MIB
1.3.6.1.4.1.9.9.719.1.32.6.1.7cucsNetworkSanNeighborEntryFiPortDnCISCO-UNIFIED-COMPUTING-NETWORK-MIB