CISCO-UNIFIED-COMPUTING-NETWORK-MIB :: cucsNetworkElementDiffMemory

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-NETWORK-MIBcucsNetworkElementDiffMemory

cucsNetworkElementDiffMemory

Module: CISCO-UNIFIED-COMPUTING-NETWORK-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-NETWORK-MIB::cucsNetworkElementDiffMemory

OID (numeric): 1.3.6.1.4.1.9.9.719.1.32.1.1.22

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS network:Element:diffMemory managed object property

What is cucsNetworkElementDiffMemory?

This OID reports, as a Gauge32, the difference between the memory UCS Manager expected the Fabric Interconnect to have and the memory it actually detected. An admin uses a nonzero value here as a direct signal of a memory-configuration mismatch on the switch, without having to manually subtract totalMemory from expectedMemory. For example, after a memory upgrade, this field should return to zero once UCS Manager rediscovers the switch; a lingering nonzero value means the new module wasn't recognized.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.32.1.1.22
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-NETWORK-MIB::cucsNetworkElementDiffMemory

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.32.1.1.22.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-NETWORK-MIB::cucsNetworkElementDiffMemory.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-NETWORK-MIB::cucsNetworkElementDiffMemory OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.32cucsNetworkObjectsCISCO-UNIFIED-COMPUTING-NETWORK-MIB
1.3.6.1.4.1.9.9.719.1.32.1cucsNetworkElementTableCISCO-UNIFIED-COMPUTING-NETWORK-MIB
1.3.6.1.4.1.9.9.719.1.32.1.1cucsNetworkElementEntryCISCO-UNIFIED-COMPUTING-NETWORK-MIB
1.3.6.1.4.1.9.9.719.1.32.1.1.22cucsNetworkElementDiffMemoryCISCO-UNIFIED-COMPUTING-NETWORK-MIB