CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB :: cucsLstorageVirtualDriveDefWriteCachePolicy

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-LSTORAGE-MIBcucsLstorageVirtualDriveDefWriteCachePolicy

cucsLstorageVirtualDriveDefWriteCachePolicy

Module: CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageVirtualDriveDefWriteCachePolicy

OID (numeric): 1.3.6.1.4.1.9.9.719.1.79.49.1.9

Node type: OBJECT-TYPE

Type: CucsLstorageVirtualDriveDefWriteCachePolicy

Access: read-only

Description: Cisco UCS lstorage:VirtualDriveDef:writeCachePolicy managed object property

What is cucsLstorageVirtualDriveDefWriteCachePolicy?

This sets the RAID controller's write-cache policy for this virtual drive, for example write-through versus write-back. An admin picks write-back specifically for higher write performance since it acknowledges writes once they hit controller cache rather than the disk, but only trusts it with a battery/capacitor-backed cache, since a power loss before flush can lose in-flight writes under write-back. Setting this to write-back-good-bbu would enable write-back caching for this virtual drive only when the controller's battery backup is confirmed healthy.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.79.49.1.9
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageVirtualDriveDefWriteCachePolicy

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.79.49.1.9.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageVirtualDriveDefWriteCachePolicy.1

Start monitoring Cisco UCS Manager-managed blade/rack servers and fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageVirtualDriveDefWriteCachePolicy OID value, configure state conditions and alerts, and monitor any Cisco UCS Manager-managed blade/rack servers and fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.79cucsLstorageObjectsCISCO-UNIFIED-COMPUTING-LSTORAGE-MIB
1.3.6.1.4.1.9.9.719.1.79.49cucsLstorageVirtualDriveDefTableCISCO-UNIFIED-COMPUTING-LSTORAGE-MIB
1.3.6.1.4.1.9.9.719.1.79.49.1cucsLstorageVirtualDriveDefEntryCISCO-UNIFIED-COMPUTING-LSTORAGE-MIB
1.3.6.1.4.1.9.9.719.1.79.49.1.9cucsLstorageVirtualDriveDefWriteCachePolicyCISCO-UNIFIED-COMPUTING-LSTORAGE-MIB