CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB :: cucsLstorageVirtualDriveDefRn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-LSTORAGE-MIBcucsLstorageVirtualDriveDefRn

cucsLstorageVirtualDriveDefRn

Module: CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageVirtualDriveDefRn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.79.49.1.3

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS lstorage:VirtualDriveDef:rn managed object property

What is cucsLstorageVirtualDriveDefRn?

This is the relative-name fragment for a virtual drive definition within its parent storage profile. Because a storage profile can define multiple virtual drives, this Rn (an index) distinguishes, for example, the boot LUN's definition from a separate data LUN's definition in the same profile. A value like virtual-drive-def-2 identifies the second virtual drive definition in this storage profile.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.79.49.1.3
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageVirtualDriveDefRn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.79.49.1.3.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageVirtualDriveDefRn.1

Start monitoring Cisco UCS Manager-managed blade/rack servers and fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageVirtualDriveDefRn OID value, configure state conditions and alerts, and monitor any Cisco UCS Manager-managed blade/rack servers and fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.79cucsLstorageObjectsCISCO-UNIFIED-COMPUTING-LSTORAGE-MIB
1.3.6.1.4.1.9.9.719.1.79.49cucsLstorageVirtualDriveDefTableCISCO-UNIFIED-COMPUTING-LSTORAGE-MIB
1.3.6.1.4.1.9.9.719.1.79.49.1cucsLstorageVirtualDriveDefEntryCISCO-UNIFIED-COMPUTING-LSTORAGE-MIB
1.3.6.1.4.1.9.9.719.1.79.49.1.3cucsLstorageVirtualDriveDefRnCISCO-UNIFIED-COMPUTING-LSTORAGE-MIB