CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB :: cucsLstorageVirtualDriveDefDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-LSTORAGE-MIBcucsLstorageVirtualDriveDefDn

cucsLstorageVirtualDriveDefDn

Module: CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageVirtualDriveDefDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.79.49.1.2

Node type: OBJECT-TYPE

Type: CucsManagedObjectDn

Access: read-only

Description: Cisco UCS lstorage:VirtualDriveDef:dn managed object property

What is cucsLstorageVirtualDriveDefDn?

This is the distinguished name of a virtual drive definition, the object that specifies a RAID logical drive's cache, IO, and access policies within a storage profile. An admin follows this Dn to locate the exact virtual drive, or LUN, definition within a storage profile whose RAID behavior they need to inspect or change. A Dn under org-root/profile-storage-HighIOPS/virtual-drive-def-1 identifies the first virtual drive defined in that storage profile.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.79.49.1.2
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageVirtualDriveDefDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.79.49.1.2.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageVirtualDriveDefDn.1

Start monitoring Cisco UCS Manager-managed blade/rack servers and fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageVirtualDriveDefDn OID value, configure state conditions and alerts, and monitor any Cisco UCS Manager-managed blade/rack servers and fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.79cucsLstorageObjectsCISCO-UNIFIED-COMPUTING-LSTORAGE-MIB
1.3.6.1.4.1.9.9.719.1.79.49cucsLstorageVirtualDriveDefTableCISCO-UNIFIED-COMPUTING-LSTORAGE-MIB
1.3.6.1.4.1.9.9.719.1.79.49.1cucsLstorageVirtualDriveDefEntryCISCO-UNIFIED-COMPUTING-LSTORAGE-MIB
1.3.6.1.4.1.9.9.719.1.79.49.1.2cucsLstorageVirtualDriveDefDnCISCO-UNIFIED-COMPUTING-LSTORAGE-MIB