All MIBs › CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB › cucsLstorageControllerRefDn
cucsLstorageControllerRefDn
Module: CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageControllerRefDn
OID (numeric): 1.3.6.1.4.1.9.9.719.1.79.57.1.2
Node type: OBJECT-TYPE
Type: CucsManagedObjectDn
Access: read-only
Description: Cisco UCS lstorage:ControllerRef:dn managed object property
What is cucsLstorageControllerRefDn?
This CucsManagedObjectDn locates this storage profile's resolved controller reference, the runtime binding of a controller qualifier to the actual controller found on the specific server the profile was applied to. While the qualifier describes the criteria in the abstract, this reference is the concrete resolved answer, so an admin diagnosing why a profile applied to the wrong controller checks this reference to see exactly what UCS Manager actually matched. A typical value is org-root/ls-Server1/board/storage-ref-1.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.79.57.1.2 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageControllerRefDn
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.79.57.1.2.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageControllerRefDn.1
Start monitoring Cisco UCS Manager-managed blade/rack servers and fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB::cucsLstorageControllerRefDn OID value, configure state conditions and alerts, and monitor any Cisco UCS Manager-managed blade/rack servers and fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.79 | cucsLstorageObjects | CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.79.57 | cucsLstorageControllerRefTable | CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.79.57.1 | cucsLstorageControllerRefEntry | CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.79.57.1.2 | cucsLstorageControllerRefDn | CISCO-UNIFIED-COMPUTING-LSTORAGE-MIB |