CISCO-UNIFIED-COMPUTING-LSBOOT-MIB :: cucsLsbootSanCatSanImageRn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-LSBOOT-MIBcucsLsbootSanCatSanImageRn

cucsLsbootSanCatSanImageRn

Module: CISCO-UNIFIED-COMPUTING-LSBOOT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-LSBOOT-MIB::cucsLsbootSanCatSanImageRn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.27.16.1.3

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS lsboot:SanCatSanImage:rn managed object property

What is cucsLsbootSanCatSanImageRn?

This SnmpAdminString RN is the naming segment this SAN image target contributes to its dn, typically san-image-primary or san-image-secondary. Because this RN encodes primary or secondary directly, an admin can tell which fabric path a given SAN image entry represents just from the dn, without inspecting its type attribute separately. A value of san-image-secondary marks this as the redundant SAN boot target, not the one tried first.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.27.16.1.3
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSBOOT-MIB::cucsLsbootSanCatSanImageRn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.27.16.1.3.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSBOOT-MIB::cucsLsbootSanCatSanImageRn.1

Start monitoring Cisco UCS service profile (boot policy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-LSBOOT-MIB::cucsLsbootSanCatSanImageRn OID value, configure state conditions and alerts, and monitor any Cisco UCS service profile (boot policy) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.27cucsLsbootObjectsCISCO-UNIFIED-COMPUTING-LSBOOT-MIB
1.3.6.1.4.1.9.9.719.1.27.16cucsLsbootSanCatSanImageTableCISCO-UNIFIED-COMPUTING-LSBOOT-MIB
1.3.6.1.4.1.9.9.719.1.27.16.1cucsLsbootSanCatSanImageEntryCISCO-UNIFIED-COMPUTING-LSBOOT-MIB
1.3.6.1.4.1.9.9.719.1.27.16.1.3cucsLsbootSanCatSanImageRnCISCO-UNIFIED-COMPUTING-LSBOOT-MIB