CISCO-UNIFIED-COMPUTING-LSBOOT-MIB :: cucsLsbootLocalLunImagePathDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-LSBOOT-MIBcucsLsbootLocalLunImagePathDn

cucsLsbootLocalLunImagePathDn

Module: CISCO-UNIFIED-COMPUTING-LSBOOT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-LSBOOT-MIB::cucsLsbootLocalLunImagePathDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.27.23.1.2

Node type: OBJECT-TYPE

Type: CucsManagedObjectDn

Access: read-only

Description: Cisco UCS lsboot:LocalLunImagePath:dn managed object property

What is cucsLsbootLocalLunImagePathDn?

This CucsManagedObjectDn is the distinguished name locating this specific path record beneath the boot policy's local-LUN boot entry. Because a local-LUN entry can carry a primary and secondary path pointing at the same virtual drive through different controller paths, this dn is what tells an admin or script exactly which of the two path records they are looking at. A value like org-root/boot-policy-Storage-Profile-Boot/local-lun-image/path-primary is typical.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.27.23.1.2
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSBOOT-MIB::cucsLsbootLocalLunImagePathDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.27.23.1.2.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSBOOT-MIB::cucsLsbootLocalLunImagePathDn.1

Start monitoring Cisco UCS service profile (boot policy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-LSBOOT-MIB::cucsLsbootLocalLunImagePathDn OID value, configure state conditions and alerts, and monitor any Cisco UCS service profile (boot policy) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.27cucsLsbootObjectsCISCO-UNIFIED-COMPUTING-LSBOOT-MIB
1.3.6.1.4.1.9.9.719.1.27.23cucsLsbootLocalLunImagePathTableCISCO-UNIFIED-COMPUTING-LSBOOT-MIB
1.3.6.1.4.1.9.9.719.1.27.23.1cucsLsbootLocalLunImagePathEntryCISCO-UNIFIED-COMPUTING-LSBOOT-MIB
1.3.6.1.4.1.9.9.719.1.27.23.1.2cucsLsbootLocalLunImagePathDnCISCO-UNIFIED-COMPUTING-LSBOOT-MIB