CISCO-UNIFIED-COMPUTING-LSBOOT-MIB :: cucsLsbootLocalDiskImagePathSlotNumber

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-LSBOOT-MIBcucsLsbootLocalDiskImagePathSlotNumber

cucsLsbootLocalDiskImagePathSlotNumber

Module: CISCO-UNIFIED-COMPUTING-LSBOOT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-LSBOOT-MIB::cucsLsbootLocalDiskImagePathSlotNumber

OID (numeric): 1.3.6.1.4.1.9.9.719.1.27.22.1.4

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS lsboot:LocalDiskImagePath:slotNumber managed object property

What is cucsLsbootLocalDiskImagePathSlotNumber?

This Gauge32 reports the physical drive-bay slot number on the server that this local-disk boot path is pinned to. Pinning boot order to a physical slot rather than a logical drive matters on blades with more than one local disk, since it tells the RAID controller and boot loader exactly which bay to read from first regardless of how disks get re-ordered logically. A value of 1 points the boot loader at the disk in physical bay 1, while a rebuilt server with the OS drive reseated in bay 2 would need this updated to 2.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.27.22.1.4
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSBOOT-MIB::cucsLsbootLocalDiskImagePathSlotNumber

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.27.22.1.4.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LSBOOT-MIB::cucsLsbootLocalDiskImagePathSlotNumber.1

Start monitoring Cisco UCS service profile (boot policy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-LSBOOT-MIB::cucsLsbootLocalDiskImagePathSlotNumber OID value, configure state conditions and alerts, and monitor any Cisco UCS service profile (boot policy) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.27cucsLsbootObjectsCISCO-UNIFIED-COMPUTING-LSBOOT-MIB
1.3.6.1.4.1.9.9.719.1.27.22cucsLsbootLocalDiskImagePathTableCISCO-UNIFIED-COMPUTING-LSBOOT-MIB
1.3.6.1.4.1.9.9.719.1.27.22.1cucsLsbootLocalDiskImagePathEntryCISCO-UNIFIED-COMPUTING-LSBOOT-MIB
1.3.6.1.4.1.9.9.719.1.27.22.1.4cucsLsbootLocalDiskImagePathSlotNumberCISCO-UNIFIED-COMPUTING-LSBOOT-MIB