All MIBs › CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB › cucsIqnpoolPoolablePoolDn
cucsIqnpoolPoolablePoolDn
Module: CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB::cucsIqnpoolPoolablePoolDn
OID (numeric): 1.3.6.1.4.1.9.9.719.1.59.5.1.5
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS iqnpool:Poolable:poolDn managed object property
What is cucsIqnpoolPoolablePoolDn?
This string holds the Dn of the specific IQN pool that this iSCSI vNIC is configured to draw its initiator name from. This is the pointer UCS Manager follows when a service profile needs an IQN assigned — if it points at the wrong pool, the host ends up presenting an initiator name from an unexpected naming scheme to the storage array. A value like 'org-root/iqn-pool-boot' means this vNIC's IQN will always come from that specific pool.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.59.5.1.5 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB::cucsIqnpoolPoolablePoolDn
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.59.5.1.5.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB::cucsIqnpoolPoolablePoolDn.1
Start monitoring Cisco UCS blade/rack server (iSCSI Qualified Name pools) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB::cucsIqnpoolPoolablePoolDn OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack server (iSCSI Qualified Name pools) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.59 | cucsIqnpoolObjects | CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB |
| 1.3.6.1.4.1.9.9.719.1.59.5 | cucsIqnpoolPoolableTable | CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB |
| 1.3.6.1.4.1.9.9.719.1.59.5.1 | cucsIqnpoolPoolableEntry | CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB |
| 1.3.6.1.4.1.9.9.719.1.59.5.1.5 | cucsIqnpoolPoolablePoolDn | CISCO-UNIFIED-COMPUTING-IQNPOOL-MIB |