CISCO-UNIFIED-COMPUTING-INITIATOR-MIB :: cucsInitiatorRequestorGrpEpDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-INITIATOR-MIBcucsInitiatorRequestorGrpEpDn

cucsInitiatorRequestorGrpEpDn

Module: CISCO-UNIFIED-COMPUTING-INITIATOR-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-INITIATOR-MIB::cucsInitiatorRequestorGrpEpDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.65.7.1.2

Node type: OBJECT-TYPE

Type: CucsManagedObjectDn

Access: read-only

Description: Cisco UCS initiator:RequestorGrpEp:dn managed object property

What is cucsInitiatorRequestorGrpEpDn?

This is the dn (Distinguished Name) that uniquely pinpoints one specific instance of a group of requestor endpoints (servers/service profiles) that share the same storage-requestor configuration, such as a common boot policy in UCS Manager's management information tree. Because a dn always encodes the full path from its parent down to this exact record, an admin or monitoring tool reading this value knows precisely which RequestorGrpEp instance it is looking at without a separate lookup — here the object sits a child grouping object holding several individual requestor endpoints. A real value would look like 'org-root/storage-profile-boot/requestor-grp-cluster1', identifying this exact record rather than any sibling instance of the same class.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.65.7.1.2
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-INITIATOR-MIB::cucsInitiatorRequestorGrpEpDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.65.7.1.2.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-INITIATOR-MIB::cucsInitiatorRequestorGrpEpDn.1

Start monitoring Cisco UCS blade/rack server (FC/iSCSI initiators) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-INITIATOR-MIB::cucsInitiatorRequestorGrpEpDn OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack server (FC/iSCSI initiators) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.65cucsInitiatorObjectsCISCO-UNIFIED-COMPUTING-INITIATOR-MIB
1.3.6.1.4.1.9.9.719.1.65.7cucsInitiatorRequestorGrpEpTableCISCO-UNIFIED-COMPUTING-INITIATOR-MIB
1.3.6.1.4.1.9.9.719.1.65.7.1cucsInitiatorRequestorGrpEpEntryCISCO-UNIFIED-COMPUTING-INITIATOR-MIB
1.3.6.1.4.1.9.9.719.1.65.7.1.2cucsInitiatorRequestorGrpEpDnCISCO-UNIFIED-COMPUTING-INITIATOR-MIB