Module: CISCO-UNIFIED-COMPUTING-INITIATOR-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-INITIATOR-MIB::cucsInitiatorLunEpId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.65.4.1.6

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS initiator:LunEp:id managed object property

What is cucsInitiatorLunEpId?

This is id on this LUN mapping, the LUN number the storage array uses to identify this specific logical unit as seen by the initiator. An admin cross-referencing a boot failure against the storage array's own LUN presentation checks this exact number to confirm the server and array agree on which LUN is meant to be, say, the boot volume. A value of 0 typically marks the first/primary LUN presented to this initiator, while a sibling entry with id 1 would be a second LUN on the same initiator.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.65.4.1.6
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-INITIATOR-MIB::cucsInitiatorLunEpId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.65.4.1.6.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-INITIATOR-MIB::cucsInitiatorLunEpId.1

Start monitoring Cisco UCS blade/rack server (FC/iSCSI initiators) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-INITIATOR-MIB::cucsInitiatorLunEpId OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack server (FC/iSCSI initiators) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.65cucsInitiatorObjectsCISCO-UNIFIED-COMPUTING-INITIATOR-MIB
1.3.6.1.4.1.9.9.719.1.65.4cucsInitiatorLunEpTableCISCO-UNIFIED-COMPUTING-INITIATOR-MIB
1.3.6.1.4.1.9.9.719.1.65.4.1cucsInitiatorLunEpEntryCISCO-UNIFIED-COMPUTING-INITIATOR-MIB
1.3.6.1.4.1.9.9.719.1.65.4.1.6cucsInitiatorLunEpIdCISCO-UNIFIED-COMPUTING-INITIATOR-MIB