All MIBs › CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB › cucsFlowctrlItemSnd
cucsFlowctrlItemSnd
Module: CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB::cucsFlowctrlItemSnd
OID (numeric): 1.3.6.1.4.1.9.9.719.1.23.2.1.7
Node type: OBJECT-TYPE
Type: CucsFlowctrlFlowControl
Access: read-only
Description: Cisco UCS flowctrl:Item:snd managed object property
What is cucsFlowctrlItemSnd?
This states whether this specific interface is configured to send pause frames to its link partner when this side becomes congested, the send-direction counterpart to rcv on the same interface. If disabled, this interface will silently drop frames under congestion rather than asking its link partner to slow down. An admin seeing unexplained drops on a specific uplink under load would check whether snd is enabled here before assuming the problem lies elsewhere on the path.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.23.2.1.7 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB::cucsFlowctrlItemSnd
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.23.2.1.7.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB::cucsFlowctrlItemSnd.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB::cucsFlowctrlItemSnd OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.23 | cucsFlowctrlObjects | CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB |
| 1.3.6.1.4.1.9.9.719.1.23.2 | cucsFlowctrlItemTable | CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB |
| 1.3.6.1.4.1.9.9.719.1.23.2.1 | cucsFlowctrlItemEntry | CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB |
| 1.3.6.1.4.1.9.9.719.1.23.2.1.7 | cucsFlowctrlItemSnd | CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB |