CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB :: cucsFlowctrlItemPrio

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB › cucsFlowctrlItemPrio

cucsFlowctrlItemPrio

Module: CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB::cucsFlowctrlItemPrio

OID (numeric): 1.3.6.1.4.1.9.9.719.1.23.2.1.5

Node type: OBJECT-TYPE

Type: CucsFlowctrlPriorityPause

Access: read-only

Description: Cisco UCS flowctrl:Item:prio managed object property

What is cucsFlowctrlItemPrio?

This states whether this specific interface's flow control is operating in priority-based (PFC, per class-of-service) mode versus classic link-level pause, which determines whether individual traffic classes on this link can be paused independently. On a link carrying both iSCSI and general Ethernet traffic in separate classes, PFC mode lets the switch pause only the congested class rather than the whole link. An admin seeing unrelated traffic stall during an iSCSI burst would check whether this field on that link is set to classic pause rather than PFC.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.23.2.1.5
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB::cucsFlowctrlItemPrio

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.23.2.1.5.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB::cucsFlowctrlItemPrio.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB::cucsFlowctrlItemPrio OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.23cucsFlowctrlObjectsCISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB
1.3.6.1.4.1.9.9.719.1.23.2cucsFlowctrlItemTableCISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB
1.3.6.1.4.1.9.9.719.1.23.2.1cucsFlowctrlItemEntryCISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB
1.3.6.1.4.1.9.9.719.1.23.2.1.5cucsFlowctrlItemPrioCISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB