All MIBs › CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB › cucsFlowctrlItemConfig
cucsFlowctrlItemConfig
Module: CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB::cucsFlowctrlItemConfig
OID (numeric): 1.3.6.1.4.1.9.9.719.1.23.2.1.8
Node type: OBJECT-TYPE
Type: CucsFlowctrlConfig
Access: read-only
Description: Cisco UCS flowctrl:Item:config managed object property
What is cucsFlowctrlItemConfig?
This is the overall flow-control configuration mode actually applied to this interface, combining priority, receive, and send behavior into one summary state, the field an admin checks to confirm the interface ended up in the flow-control mode intended by its policy. It is the practical bottom line an admin reads instead of cross-referencing prio, rcv, and snd separately for a quick sanity check. A value that doesn't match what the attached policy Definition specifies would flag this specific interface as out of sync with its intended configuration.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.23.2.1.8 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB::cucsFlowctrlItemConfig
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.23.2.1.8.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB::cucsFlowctrlItemConfig.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB::cucsFlowctrlItemConfig OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.23 | cucsFlowctrlObjects | CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB |
| 1.3.6.1.4.1.9.9.719.1.23.2 | cucsFlowctrlItemTable | CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB |
| 1.3.6.1.4.1.9.9.719.1.23.2.1 | cucsFlowctrlItemEntry | CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB |
| 1.3.6.1.4.1.9.9.719.1.23.2.1.8 | cucsFlowctrlItemConfig | CISCO-UNIFIED-COMPUTING-FLOWCTRL-MIB |