CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB :: cucsFirmwareSystemCompCheckResultNonCompDns

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FIRMWARE-MIBcucsFirmwareSystemCompCheckResultNonCompDns

cucsFirmwareSystemCompCheckResultNonCompDns

Module: CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwareSystemCompCheckResultNonCompDns

OID (numeric): 1.3.6.1.4.1.9.9.719.1.22.44.1.7

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS firmware:SystemCompCheckResult:nonCompDns managed object property

What is cucsFirmwareSystemCompCheckResultNonCompDns?

This is a list of Distinguished Names of all objects affected by this same non-compliance finding, useful when one root cause - such as an outdated catalog entry - produces the identical finding across many servers at once. An admin can use this field to remediate every affected server in one pass rather than discovering them one finding at a time. A finding whose nonCompDns lists fifteen blade Dns tells the admin this is a fleet-wide issue, not an isolated one.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.22.44.1.7
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwareSystemCompCheckResultNonCompDns

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.22.44.1.7.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwareSystemCompCheckResultNonCompDns.1

Start monitoring Cisco UCS blade server / fabric interconnect / chassis (firmware) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwareSystemCompCheckResultNonCompDns OID value, configure state conditions and alerts, and monitor any Cisco UCS blade server / fabric interconnect / chassis (firmware) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.22cucsFirmwareObjectsCISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
1.3.6.1.4.1.9.9.719.1.22.44cucsFirmwareSystemCompCheckResultTableCISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
1.3.6.1.4.1.9.9.719.1.22.44.1cucsFirmwareSystemCompCheckResultEntryCISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
1.3.6.1.4.1.9.9.719.1.22.44.1.7cucsFirmwareSystemCompCheckResultNonCompDnsCISCO-UNIFIED-COMPUTING-FIRMWARE-MIB