CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB :: cucsFirmwareSecondControllerChassisConstraintMinCmcVersion

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FIRMWARE-MIBcucsFirmwareSecondControllerChassisConstraintMinCmcVersion

cucsFirmwareSecondControllerChassisConstraintMinCmcVersion

Module: CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwareSecondControllerChassisConstraintMinCmcVersion

OID (numeric): 1.3.6.1.4.1.9.9.719.1.22.89.1.4

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS firmware:SecondControllerChassisConstraint:minCmcVersio n managed object property

What is cucsFirmwareSecondControllerChassisConstraintMinCmcVersion?

This is the minimum CMC (chassis management controller) firmware version required before a chassis with a redundant second storage controller is considered compliant under this constraint, distinct from a per-server CIMC minimum since this rule is scoped to the chassis. A chassis on an older CMC than this value would show as non-compliant specifically because of its second controller's support requirements. A value like '4.1(1c)' sets the floor a S3260-style chassis must clear before its second controller is deemed properly supported.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.22.89.1.4
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwareSecondControllerChassisConstraintMinCmcVersion

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.22.89.1.4.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwareSecondControllerChassisConstraintMinCmcVersion.1

Start monitoring Cisco UCS blade server / fabric interconnect / chassis (firmware) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwareSecondControllerChassisConstraintMinCmcVersion OID value, configure state conditions and alerts, and monitor any Cisco UCS blade server / fabric interconnect / chassis (firmware) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.22cucsFirmwareObjectsCISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
1.3.6.1.4.1.9.9.719.1.22.89cucsFirmwareSecondControllerChassisConstraintTableCISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
1.3.6.1.4.1.9.9.719.1.22.89.1cucsFirmwareSecondControllerChassisConstraintEntryCISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
1.3.6.1.4.1.9.9.719.1.22.89.1.4cucsFirmwareSecondControllerChassisConstraintMinCmcVersionCISCO-UNIFIED-COMPUTING-FIRMWARE-MIB