CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB :: cucsFirmwarePCHStorageConfigConstraintMinCimcVersion

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FIRMWARE-MIBcucsFirmwarePCHStorageConfigConstraintMinCimcVersion

cucsFirmwarePCHStorageConfigConstraintMinCimcVersion

Module: CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwarePCHStorageConfigConstraintMinCimcVersion

OID (numeric): 1.3.6.1.4.1.9.9.719.1.22.71.1.5

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS firmware:PCHStorageConfigConstraint:minCimcVersion managed object property

What is cucsFirmwarePCHStorageConfigConstraintMinCimcVersion?

This value is a firmware-compatibility rule: the minimum CIMC (onboard server management controller) version a server must already be running before UCS Manager will let it switch to a particular PCH (platform controller hub) storage/RAID configuration. On a specific blade or rack server, if its actual CIMC version is older than what is stored here, UCS Manager blocks that PCH storage-mode change rather than risk an unsupported firmware/RAID combination. For example, a value like '4.1(3a)' means any server still on CIMC 4.0 cannot apply that PCH storage mode until it is upgraded.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.22.71.1.5
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwarePCHStorageConfigConstraintMinCimcVersion

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.22.71.1.5.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwarePCHStorageConfigConstraintMinCimcVersion.1

Start monitoring Cisco UCS blade server / fabric interconnect / chassis (firmware) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwarePCHStorageConfigConstraintMinCimcVersion OID value, configure state conditions and alerts, and monitor any Cisco UCS blade server / fabric interconnect / chassis (firmware) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.22cucsFirmwareObjectsCISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
1.3.6.1.4.1.9.9.719.1.22.71cucsFirmwarePCHStorageConfigConstraintTableCISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
1.3.6.1.4.1.9.9.719.1.22.71.1cucsFirmwarePCHStorageConfigConstraintEntryCISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
1.3.6.1.4.1.9.9.719.1.22.71.1.5cucsFirmwarePCHStorageConfigConstraintMinCimcVersionCISCO-UNIFIED-COMPUTING-FIRMWARE-MIB