All MIBs › CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB › cucsFirmwareAckAcked
cucsFirmwareAckAcked
Module: CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwareAckAcked
OID (numeric): 1.3.6.1.4.1.9.9.719.1.22.25.1.4
Node type: OBJECT-TYPE
Type: DateAndTime
Access: read-only
Description: Cisco UCS firmware:Ack:acked managed object property
What is cucsFirmwareAckAcked?
This is the timestamp at which this specific pending firmware acknowledgment was actually acknowledged by an admin, allowing the disruptive action it was gating to proceed. An admin checks this field to confirm exactly when approval was given for a specific firmware change, useful when auditing who approved a disruptive reboot and when. A populated Acked timestamp on this object means the gated action for that specific hardware has already been cleared to run.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.22.25.1.4 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwareAckAcked
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.22.25.1.4.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwareAckAcked.1
Start monitoring Cisco UCS blade server / fabric interconnect / chassis (firmware) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB::cucsFirmwareAckAcked OID value, configure state conditions and alerts, and monitor any Cisco UCS blade server / fabric interconnect / chassis (firmware) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.22 | cucsFirmwareObjects | CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB |
| 1.3.6.1.4.1.9.9.719.1.22.25 | cucsFirmwareAckTable | CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB |
| 1.3.6.1.4.1.9.9.719.1.22.25.1 | cucsFirmwareAckEntry | CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB |
| 1.3.6.1.4.1.9.9.719.1.22.25.1.4 | cucsFirmwareAckAcked | CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB |