All MIBs › CISCO-UNIFIED-COMPUTING-FABRIC-MIB › cucsFabricVsanOperState
cucsFabricVsanOperState
Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricVsanOperState
OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.62.1.17
Node type: OBJECT-TYPE
Type: CucsFabricVsanOperState
Access: read-only
Description: Cisco UCS fabric:Vsan:operState managed object property
What is cucsFabricVsanOperState?
This is the operational state of this VSAN - whether it is actually applied and forwarding Fibre Channel traffic on the fabric, independent of its administrative configuration. A VSAN can be fully configured yet fail to apply if its ID conflicts with another VSAN on the same fabric or its FCoE VLAN mapping is invalid, so this is the field an admin checks first when storage traffic isn't passing on a VSAN that appears correctly set up. VSAN Storage-VSAN-Prod might show operState applied on Fabric A but failed on Fabric B due to an ID conflict specific to that fabric side.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.62.1.17 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricVsanOperState
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.62.1.17.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricVsanOperState.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricVsanOperState OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.19 | cucsFabricObjects | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.19.62 | cucsFabricVsanTable | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.19.62.1 | cucsFabricVsanEntry | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.19.62.1.17 | cucsFabricVsanOperState | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |