CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricVlanEpOverlapStateForB

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricVlanEpOverlapStateForB

cucsFabricVlanEpOverlapStateForB

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricVlanEpOverlapStateForB

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.61.1.25

Node type: OBJECT-TYPE

Type: CucsFabricVlanOverlapState

Access: read-only

Description: Cisco UCS fabric:VlanEp:overlapStateForB managed object property

What is cucsFabricVlanEpOverlapStateForB?

This is the same per-endpoint overlap check as above, but for Fabric Interconnect B. Together with the A-side field, this lets an admin see, endpoint by endpoint, exactly which physical ports on which fabric side are impacted by a given VLAN ID collision, rather than treating the whole VLAN as uniformly broken. A port on Fabric B carrying a VLAN with no ID conflicts there would show this field as no-overlap even while the same VLAN's Fabric-A binding shows overlap due to a Fabric-A-only naming clash.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.61.1.25
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricVlanEpOverlapStateForB

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.61.1.25.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricVlanEpOverlapStateForB.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricVlanEpOverlapStateForB OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.61cucsFabricVlanEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.61.1cucsFabricVlanEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.61.1.25cucsFabricVlanEpOverlapStateForBCISCO-UNIFIED-COMPUTING-FABRIC-MIB