cucsFabricVlanEpIfType

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricVlanEpIfType

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.61.1.7

Node type: OBJECT-TYPE

Type: CucsNetworkVnetEpIfType

Access: read-only

Description: Cisco UCS fabric:VlanEp:ifType managed object property

What is cucsFabricVlanEpIfType?

This reports the interface type of this VLAN endpoint - for instance whether the underlying interface is a physical port, a port-channel, or a virtual interface. An admin troubleshooting a VLAN outage checks this field to know immediately whether to go inspect a single physical uplink or an aggregated port-channel bundle, since the failure mode and the commands to check differ between the two. A VLAN trunked over a redundant pair of 40G uplinks bonded together would show this field as an aggregation type rather than a single physical port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.61.1.7
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricVlanEpIfType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.61.1.7.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricVlanEpIfType.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricVlanEpIfType OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.61cucsFabricVlanEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.61.1cucsFabricVlanEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.61.1.7cucsFabricVlanEpIfTypeCISCO-UNIFIED-COMPUTING-FABRIC-MIB