All MIBs › CISCO-UNIFIED-COMPUTING-FABRIC-MIB › cucsFabricFcoeVsanPortEpSlotId
cucsFabricFcoeVsanPortEpSlotId
Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcoeVsanPortEpSlotId
OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.64.1.18
Node type: OBJECT-TYPE
Type: CucsFabricFcoeVsanPortEpSlotId
Access: read-only
Description: Cisco UCS fabric:FcoeVsanPortEp:slotId managed object property
What is cucsFabricFcoeVsanPortEpSlotId?
This value identifies the slot number associated with this VSAN's endpoint on an FCoE member port on its fabric interconnect or chassis. Along with portId, this tells an admin exactly which hardware slot to physically inspect when this VSAN's endpoint on an FCoE member port needs a cable, transceiver, or module check. A value of '1' would place this VSAN's endpoint on an FCoE member port in expansion slot 1 of the fabric interconnect.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.64.1.18 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcoeVsanPortEpSlotId
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.64.1.18.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcoeVsanPortEpSlotId.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcoeVsanPortEpSlotId OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.19 | cucsFabricObjects | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.19.64 | cucsFabricFcoeVsanPortEpTable | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.19.64.1 | cucsFabricFcoeVsanPortEpEntry | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.19.64.1.18 | cucsFabricFcoeVsanPortEpSlotId | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |