CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricFcoeEstcEpOperStateReason

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricFcoeEstcEpOperStateReason

cucsFabricFcoeEstcEpOperStateReason

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcoeEstcEpOperStateReason

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.40.1.26

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS fabric:FcoeEstcEp:operStateReason managed object property

What is cucsFabricFcoeEstcEpOperStateReason?

The real DESCRIPTION field here is just the auto-generated stub "Cisco UCS fabric:FcoeEstcEp:operStateReason managed object property", so it carries no real prose -- but the property name and its SnmpAdminString type tell you what it holds: It holds a short text reason code explaining why this FCoE storage uplink port's operState is what it currently is. When operState on this FCoE storage uplink port is anything other than a clean "up", this field is where UCS Manager writes the specific cause -- for example that the SFP is absent, the peer never came up, or the link was administratively shut down -- so an admin does not have to guess at troubleshooting time. A typical value might be "link-down" or "sfp-not-present", telling the admin exactly what to go check on this particular FCoE storage uplink port rather than a bare failure flag.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.40.1.26
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcoeEstcEpOperStateReason

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.40.1.26.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcoeEstcEpOperStateReason.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsFabricFcoeEstcEpOperStateReason.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcoeEstcEpOperStateReason OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.40cucsFabricFcoeEstcEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.40.1cucsFabricFcoeEstcEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.40.1.26cucsFabricFcoeEstcEpOperStateReasonCISCO-UNIFIED-COMPUTING-FABRIC-MIB