CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricFcVsanPortEpOperStateReason

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricFcVsanPortEpOperStateReason

cucsFabricFcVsanPortEpOperStateReason

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcVsanPortEpOperStateReason

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.39.1.24

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS fabric:FcVsanPortEp:operStateReason managed object property

What is cucsFabricFcVsanPortEpOperStateReason?

The real DESCRIPTION field here is just the auto-generated stub "Cisco UCS fabric:FcVsanPortEp:operStateReason managed object property", so it carries no real prose -- but the property name and its SnmpAdminString type tell you what it holds: It holds a short text reason code explaining why this VSAN port endpoint's operState is what it currently is. When operState on this VSAN port endpoint is anything other than a clean "up", this field is where UCS Manager writes the specific cause -- for example that the SFP is absent, the peer never came up, or the link was administratively shut down -- so an admin does not have to guess at troubleshooting time. A typical value might be "link-down" or "sfp-not-present", telling the admin exactly what to go check on this particular VSAN port endpoint rather than a bare failure flag.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.39.1.24
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcVsanPortEpOperStateReason

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.39.1.24.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcVsanPortEpOperStateReason.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcVsanPortEpOperStateReason OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.39cucsFabricFcVsanPortEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.39.1cucsFabricFcVsanPortEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.39.1.24cucsFabricFcVsanPortEpOperStateReasonCISCO-UNIFIED-COMPUTING-FABRIC-MIB