CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricFcVsanPcEpDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricFcVsanPcEpDn

cucsFabricFcVsanPcEpDn

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcVsanPcEpDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.65.1.5

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS fabric:FcVsanPc:epDn managed object property

What is cucsFabricFcVsanPcEpDn?

The real DESCRIPTION field here is just the auto-generated stub "Cisco UCS fabric:FcVsanPc:epDn managed object property", so it carries no real prose -- but the property name and its SnmpAdminString type tell you what it holds: It holds the dn of the physical port endpoint object underlying this VSAN port-channel, linking the logical port-channel or profile row back to the actual hardware port it rides on. Because an FC port-channel that has been scoped to a particular VSAN, letting that VSAN's traffic ride a bundled, redundant uplink, this field is how UCS Manager ties this logical object back to one concrete piece of hardware -- so an admin following a fault or a cable pull can jump straight from this VSAN port-channel to the exact physical port responsible. A value here might look like sys/switch-B/fc-slot-3/fc-21, pointing at the specific physical uplink that backs this VSAN port-channel.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.65.1.5
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcVsanPcEpDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.65.1.5.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcVsanPcEpDn.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcVsanPcEpDn OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.65cucsFabricFcVsanPcTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.65.1cucsFabricFcVsanPcEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.65.1.5cucsFabricFcVsanPcEpDnCISCO-UNIFIED-COMPUTING-FABRIC-MIB