CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricFcSanPcPeerDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricFcSanPcPeerDn

cucsFabricFcSanPcPeerDn

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanPcPeerDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.37.1.12

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS fabric:FcSanPc:peerDn managed object property

What is cucsFabricFcSanPcPeerDn?

The real DESCRIPTION field here is just the auto-generated stub "Cisco UCS fabric:FcSanPc:peerDn managed object property", so it carries no real prose -- but the property name and its SnmpAdminString type tell you what it holds: It holds the dn of the object on the far end of this FC SAN port-channel's connection -- effectively recording what the SAN switch-side port-channel it is bundled to. This is the field that lets UCS Manager (and anything polling this OID) trace a wire all the way through: given this FC SAN port-channel, you can look up peerDn to find exactly which switch, port, or port-channel object it is paired with, without having to cross-reference cabling diagrams by hand. For this FC SAN port-channel, peerDn might read something like fc-switch/slot-6/port-7, naming the specific device and port on the SAN side.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.37.1.12
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanPcPeerDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.37.1.12.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanPcPeerDn.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanPcPeerDn OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.37cucsFabricFcSanPcTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.37.1cucsFabricFcSanPcEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.37.1.12cucsFabricFcSanPcPeerDnCISCO-UNIFIED-COMPUTING-FABRIC-MIB