CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricFcSanEpPeerChassisId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricFcSanEpPeerChassisId

cucsFabricFcSanEpPeerChassisId

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanEpPeerChassisId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.36.1.22

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS fabric:FcSanEp:peerChassisId managed object property

What is cucsFabricFcSanEpPeerChassisId?

The real DESCRIPTION field here is just the auto-generated stub "Cisco UCS fabric:FcSanEp:peerChassisId managed object property", so it carries no real prose -- but the property name and its Gauge32 type tell you what it holds: It holds the chassis identifier of whatever sits on the far end of this FC SAN uplink port's physical connection, when that far end is a chassis IOM rather than another switch. On the upstream Fibre Channel SAN switch port (an MDS or Nexus) it is cabled to, this is not really applicable, so this field typically reports 0 for this FC SAN uplink port -- a nonzero value here would actually be a sign this port is unexpectedly wired to a blade chassis instead of the SAN. Expect this to read 0 for a normal SAN-facing FC SAN uplink port; a nonzero value such as 2 would flag a wiring mistake worth investigating.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.36.1.22
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanEpPeerChassisId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.36.1.22.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanEpPeerChassisId.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanEpPeerChassisId OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.36cucsFabricFcSanEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.36.1cucsFabricFcSanEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.36.1.22cucsFabricFcSanEpPeerChassisIdCISCO-UNIFIED-COMPUTING-FABRIC-MIB