CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricFcSanEpPeerAggrPortId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricFcSanEpPeerAggrPortId

cucsFabricFcSanEpPeerAggrPortId

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanEpPeerAggrPortId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.36.1.29

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS fabric:FcSanEp:peerAggrPortId managed object property

What is cucsFabricFcSanEpPeerAggrPortId?

The real DESCRIPTION field here is just the auto-generated stub "Cisco UCS fabric:FcSanEp:peerAggrPortId managed object property", so it carries no real prose -- but the property name and its Gauge32 type tell you what it holds: It holds the breakout sub-port index on the far end that this FC SAN uplink port is wired to, mirroring aggrPortId but describing the peer side of the connection. This lets UCS Manager record a full breakout-to-breakout mapping for the upstream Fibre Channel SAN switch port (an MDS or Nexus) it is cabled to, so a mis-cabled lane (say, local lane 1 patched to peer lane 3) shows up as a mismatch between this field and aggrPortId rather than as an unexplained link failure. If this FC SAN uplink port's local lane 1 connects straight across to lane 1 on the peer, this field reads 4; any other value would mean the lanes are crossed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.36.1.29
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanEpPeerAggrPortId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.36.1.29.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanEpPeerAggrPortId.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsFabricFcSanEpPeerAggrPortId.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanEpPeerAggrPortId OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.36cucsFabricFcSanEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.36.1cucsFabricFcSanEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.36.1.29cucsFabricFcSanEpPeerAggrPortIdCISCO-UNIFIED-COMPUTING-FABRIC-MIB