CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricFcSanEpFillPattern

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricFcSanEpFillPattern

cucsFabricFcSanEpFillPattern

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanEpFillPattern

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.36.1.27

Node type: OBJECT-TYPE

Type: CucsFabricFillPattern

Access: read-only

Description: Cisco UCS fabric:FcSanEp:fillPattern managed object property

What is cucsFabricFcSanEpFillPattern?

The real DESCRIPTION field here is just the auto-generated stub "Cisco UCS fabric:FcSanEp:fillPattern managed object property", so it carries no real prose -- but the property name and its CucsFabricFillPattern type tell you what it holds: It holds the FC idle/fill-word pattern that has been negotiated on this FC SAN uplink port's link -- either the older "ARBFF" pattern or the newer "IDLE" pattern used at higher FC speeds. This matters specifically for FC links because the two ends of the upstream Fibre Channel SAN switch port (an MDS or Nexus) it is cabled to must agree on the fill pattern for the link to initialize cleanly at speeds of 8Gbps and above; a mismatch here on this FC SAN uplink port is a classic cause of a link that will not come up even though both SFPs look fine. A healthy 16Gbps link on this FC SAN uplink port would typically show "idle", while an older 2Gbps or 4Gbps link might still negotiate "arbff".

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.36.1.27
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanEpFillPattern

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.36.1.27.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanEpFillPattern.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcSanEpFillPattern OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.36cucsFabricFcSanEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.36.1cucsFabricFcSanEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.36.1.27cucsFabricFcSanEpFillPatternCISCO-UNIFIED-COMPUTING-FABRIC-MIB