CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricFcMonSrcRefSourceDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricFcMonSrcRefSourceDn

cucsFabricFcMonSrcRefSourceDn

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcMonSrcRefSourceDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.34.1.5

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS fabric:FcMonSrcRef:sourceDn managed object property

What is cucsFabricFcMonSrcRefSourceDn?

This SnmpAdminString field holds the Distinguished Name of the actual object (a port, VSAN, or endpoint) that this FC monitor source reference identifies as the traffic source. For a linking record identifying exactly which object (port, VSAN, or endpoint) is supplying the mirrored traffic for an FC monitoring session, this is the concrete pointer that lets UCS Manager resolve an abstract 'source' reference in a monitoring session down to one specific, real hardware object whose frames get copied. In a working session this resolves to the DN of a real FC port or VSAN object; a blank value here would mean the source reference is currently unresolved, and the session can't actually be capturing anything.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.34.1.5
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcMonSrcRefSourceDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.34.1.5.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcMonSrcRefSourceDn.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsFabricFcMonSrcRefSourceDn.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcMonSrcRefSourceDn OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.34cucsFabricFcMonSrcRefTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.34.1cucsFabricFcMonSrcRefEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.34.1.5cucsFabricFcMonSrcRefSourceDnCISCO-UNIFIED-COMPUTING-FABRIC-MIB