CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricFcMonSrcEpRn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricFcMonSrcEpRn

cucsFabricFcMonSrcEpRn

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcMonSrcEpRn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.33.1.3

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS fabric:FcMonSrcEp:rn managed object property

What is cucsFabricFcMonSrcEpRn?

This SnmpAdminString holds the Relative Name (RN) — the final path segment that, appended to the parent's DN, produces the full DN of this FC monitoring session's source port. For this FC monitoring session's source port, the RN is generated from the object's own key properties (such as an ID, port number, or session number) so that every instance of the physical FC port whose traffic is being mirrored/copied for an FC monitoring session gets a distinct, non-colliding suffix under its parent container. A typical RN value here looks like a short hyphenated token, for instance one incorporating the number 37, rather than a full path.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.33.1.3
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcMonSrcEpRn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.33.1.3.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcMonSrcEpRn.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcMonSrcEpRn OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.33cucsFabricFcMonSrcEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.33.1cucsFabricFcMonSrcEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.33.1.3cucsFabricFcMonSrcEpRnCISCO-UNIFIED-COMPUTING-FABRIC-MIB