All MIBs › CISCO-UNIFIED-COMPUTING-FABRIC-MIB › cucsFabricFcMonDestEpSlotId
cucsFabricFcMonDestEpSlotId
Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcMonDestEpSlotId
OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.29.1.17
Node type: OBJECT-TYPE
Type: CucsFabricFcMonDestEpSlotId
Access: read-only
Description: Cisco UCS fabric:FcMonDestEp:slotId managed object property
What is cucsFabricFcMonDestEpSlotId?
This Gauge32 field records the physical slot number within its chassis that this endpoint's port resides on or connects toward. For the physical FC port designated to receive the mirrored/copied traffic for an FC monitoring session, slot number combined with chassis and port number is what lets a technician walk up to the exact physical hardware this SNMP object represents. For example this value might read slot 1, pinpointing a specific I/O module or fabric extender bay rather than the chassis as a whole.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.29.1.17 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcMonDestEpSlotId
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.29.1.17.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcMonDestEpSlotId.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricFcMonDestEpSlotId OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.19 | cucsFabricObjects | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.19.29 | cucsFabricFcMonDestEpTable | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.19.29.1 | cucsFabricFcMonDestEpEntry | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.19.29.1.17 | cucsFabricFcMonDestEpSlotId | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |