CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricEthEstcPcEpSlotId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricEthEstcPcEpSlotId

cucsFabricEthEstcPcEpSlotId

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricEthEstcPcEpSlotId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.68.1.21

Node type: OBJECT-TYPE

Type: CucsFabricEthEstcPcEpSlotId

Access: read-only

Description: Cisco UCS fabric:EthEstcPcEp:slotId managed object property

What is cucsFabricEthEstcPcEpSlotId?

This field (CucsFabricEthEstcPcEpSlotId) records the IOM/module slot number that one physical port that is a member link of a NAS-storage-connectivity (Estc) port-channel occupies within its chassis. Slot numbering matters here because UCS chassis typically have two IOMs (slot 1 and slot 2) feeding the two fabric interconnects, so this value tells the admin which physical module and which fabric side this NAS-storage port-channel member port is wired through. A value of '1' points to IOM slot 1; '2' would be the redundant IOM in slot 2.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.68.1.21
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricEthEstcPcEpSlotId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.68.1.21.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricEthEstcPcEpSlotId.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricEthEstcPcEpSlotId OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.68cucsFabricEthEstcPcEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.68.1cucsFabricEthEstcPcEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.68.1.21cucsFabricEthEstcPcEpSlotIdCISCO-UNIFIED-COMPUTING-FABRIC-MIB