cucsFabricEthEstcPcEpPeerDn

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricEthEstcPcEpPeerDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.68.1.17

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS fabric:EthEstcPcEp:peerDn managed object property

What is cucsFabricEthEstcPcEpPeerDn?

This field (SnmpAdminString) holds the Distinguished Name of the object at the far end (peer) of one physical port that is a member link of a NAS-storage-connectivity (Estc) port-channel. This is the direct pointer an admin follows to jump straight to the connected device's own management object, which matters for NAS-storage port-channel member port when confirming both ends of a link agree on speed, VLANs, or state during a mismatch investigation. A value such as 'sys/chassis-3/slot-2/fabric-ext/switch-eth/port-1' would identify exactly which peer port this link terminates on.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.68.1.17
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricEthEstcPcEpPeerDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.68.1.17.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricEthEstcPcEpPeerDn.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricEthEstcPcEpPeerDn OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.68cucsFabricEthEstcPcEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.68.1cucsFabricEthEstcPcEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.68.1.17cucsFabricEthEstcPcEpPeerDnCISCO-UNIFIED-COMPUTING-FABRIC-MIB