CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricComputeSlotEpPresencePath

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricComputeSlotEpPresencePath

cucsFabricComputeSlotEpPresencePath

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricComputeSlotEpPresencePath

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.3.1.48

Node type: OBJECT-TYPE

Type: CucsEquipmentConnectionStatus

Access: read-only

Description: Cisco UCS fabric:ComputeSlotEp:presencePath managed object property

What is cucsFabricComputeSlotEpPresencePath?

This reports the presence status specifically along this slot's redundant connectivity path, as opposed to overall physical presence. For this chassis slot's endpoint for whatever blade currently occupies it, presencePath narrows the general 'is hardware here' question down to a specific redundant path, which is what an admin checks when a blade is clearly seated but only one of its two fabric paths is reporting presence correctly. Seeing presencePath read 'A' but not 'B' here would tell an admin this slot's blade is only being detected over the fabric-A path, indicating a fabric-B cabling or IOM issue.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.3.1.48
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricComputeSlotEpPresencePath

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.3.1.48.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricComputeSlotEpPresencePath.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricComputeSlotEpPresencePath OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.3cucsFabricComputeSlotEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.3.1cucsFabricComputeSlotEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.3.1.48cucsFabricComputeSlotEpPresencePathCISCO-UNIFIED-COMPUTING-FABRIC-MIB