All MIBs › CISCO-UNIFIED-COMPUTING-FABRIC-MIB › cucsFabricComputeMSlotEpFruIdentTrigTs
cucsFabricComputeMSlotEpFruIdentTrigTs
Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricComputeMSlotEpFruIdentTrigTs
OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.131.1.12
Node type: OBJECT-TYPE
Type: Unsigned64
Access: read-only
Description: Cisco UCS fabric:ComputeMSlotEp:fruIdentTrigTs managed object property
What is cucsFabricComputeMSlotEpFruIdentTrigTs?
This is a UCS-internal timestamp recording when a FRU (field-replaceable unit) identification/locator action was last triggered for this UCS M-Series modular server slot endpoint. An admin who just told UCS Manager to blink the locator LED on the hardware behind the M-Series slot (to physically find it in a crowded rack) can confirm the command actually registered by seeing this timestamp update. A recent timestamp confirms a locator/identify action was triggered moments ago; an old or zero value means no such action has been requested recently.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.131.1.12 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricComputeMSlotEpFruIdentTrigTs
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.131.1.12.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricComputeMSlotEpFruIdentTrigTs.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricComputeMSlotEpFruIdentTrigTs OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.19 | cucsFabricObjects | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.19.131 | cucsFabricComputeMSlotEpTable | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.19.131.1 | cucsFabricComputeMSlotEpEntry | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.19.131.1.12 | cucsFabricComputeMSlotEpFruIdentTrigTs | CISCO-UNIFIED-COMPUTING-FABRIC-MIB |