CISCO-UNIFIED-COMPUTING-FABRIC-MIB :: cucsFabricCartridgeSlotEpPresence

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FABRIC-MIBcucsFabricCartridgeSlotEpPresence

cucsFabricCartridgeSlotEpPresence

Module: CISCO-UNIFIED-COMPUTING-FABRIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricCartridgeSlotEpPresence

OID (numeric): 1.3.6.1.4.1.9.9.719.1.19.127.1.38

Node type: OBJECT-TYPE

Type: CucsEquipmentSlotStatus

Access: read-only

Description: Cisco UCS fabric:CartridgeSlotEp:presence managed object property

What is cucsFabricCartridgeSlotEpPresence?

This reports whether hardware is physically present, empty, or mismatched in the bay represented by this cartridge slot (bay). An admin scripting an inventory report reads this field to distinguish an intentionally empty bay from one where UCS expected hardware but detected none, which is the difference between planned capacity and a possible seating problem on the slot. A value like 'equipped' confirms a cartridge is physically seated; 'empty' confirms the bay is intentionally vacant.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.127.1.38
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricCartridgeSlotEpPresence

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.19.127.1.38.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricCartridgeSlotEpPresence.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FABRIC-MIB::cucsFabricCartridgeSlotEpPresence OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.19cucsFabricObjectsCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.127cucsFabricCartridgeSlotEpTableCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.127.1cucsFabricCartridgeSlotEpEntryCISCO-UNIFIED-COMPUTING-FABRIC-MIB
1.3.6.1.4.1.9.9.719.1.19.127.1.38cucsFabricCartridgeSlotEpPresenceCISCO-UNIFIED-COMPUTING-FABRIC-MIB